Experiment
25 - Mylar
window
Cell:
- Cathode:
2 cm of exposed 0.25mm Ag wire as close as possible to Mylar window
- window: 1.5 cm x 1.5 cm hole machined
in side of cell with Mylar window glued over it (with Devcon clear
epoxy)
- 1 cm x 1 cm
Landauer CR-39 chip on the outside of the Mylar
- Anode:
Approximately 5 cm of 0.5 mm Pt wire with Pt screen spot welded on
end
- without
magnets
- a
"witness" piece of CR-39 was taped to the the outside of the cell
(away from the cathode)
Electrolyte:
- 27.5
gm D2O + 0.318 gm LiCl + 0.036 gm PdCl2
- (2/7
of the TGP PdCl2 because we have 2 cm of cathode wire and the TGP uses 7)
Procedure:
Etch:
Results
(Started on 2.6.07 Ended on 2.24.07):
- No significant tracks
- side facing cathode: 106 /cm^2
- side facing away: 138 /cm^2
- witness piece facing cell: 61 /cm^2
- witness piece facing away: 159 /cm^2