Experiment 14 - NiCl2
10 mA for 10 days
100 mA for 2 days
Etch:
6.5M NaOH at 68°C for 6 hours
Results (Started on 1.12.07 Ended on 1.25.07):
By the second day, the cell was full of the black cloud. It sat at 10mA waiting for this to clear but it never did. After one day at 100mA, it finally condensed
Most of the "stuff" was in a loose blob off to one side from the cathode wire. The wire itself was coated with a hard layer, but very thin.
Tracks down the middle.